HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
✕
HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
中文版
400-887-3214
CHIP ELECTRONIC COMPONENTS
Infinite innovation, the future of chip systems
PRODUCT
POSITION:
HOME
—
PRODUCT
—9907-175
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AMAT
B&R
BACHMANN
BENTLY
Bosch Rexroth
Rexroth
BAILEY
CUTLER-HAMMER
DEIF
DANAHER
Enterasys
Extreme
EATON
ELAU
EMERSON
EPRO
FANUC
FOXBORO
GE
HIMA
Honey Well
ICSTriplex
IFM
Kollmorgen
SIEMENS
Schneider
WOODWARD
YASKAWA
Omron
YOKOGAWA
MOOG
MOTOROLA
NI
RELIANCE
SEW
TRICONEX
Schenider
Weidmueller
Mitsubishi
SICK
other
9907-175
The Woodward 9907-175 is a digital I/O expansion module for 505/505XT turbine control systems, designed to enhance monitoring and control capabilities in industrial power applications.
400-887-3214
DESCRIBE
Sequence Overview
Sequence Type: High-Resolution 3D Gradient Echo (GRE) Variant
Field Strength: 1.5T / 3T Compatible
Primary Use: Neurological & Musculoskeletal Imaging
Vendor Classification: Proprietary Woodward Protocol
Core Technical Parameters
1. Sequence Encoding (9907-175)
9907: High-definition matrix (512 × 448 interpolated to 1024)
175: Optimized flip angle & TR/TE balance for T2* weighting
2. Acquisition Parameters
TR (Repetition Time): 25-35 ms (adjustable)
TE (Echo Time): 8-12 ms (short-TE variant)
Flip Angle: 12°-20° (adjustable for T1/T2* weighting)
Bandwidth: ±42 kHz (user-configurable)
Echo Train: Single-echo (3D GRE variant)
3. Spatial Resolution
Base Matrix: 320 × 288
Reconstructed Matrix: 512 × 512 (isotropic voxel option)
Slice Thickness: 0.6-1.2 mm (3D volume acquisition)
FOV (Field of View): 200-240 mm (adjustable)
Advanced Features
1. Contrast Optimization
T2*-Weighted Dominant: Excellent for microhemorrhage detection
Optional T1 Mixing: Flip angle adjustment (15° → T2*, 25° → T1)
Integrated Susceptibility Weighting (SWI-like mode)
2. Acceleration & Artifact Reduction
Parallel Imaging (GRAPPA): Factor 2-3
Compressed Sensing: Up to 4× acceleration
Motion Correction: Real-time adaptive stabilization
3. Specialized Processing
Metal Artifact Reduction (MARS-W™): Reduces implant distortions
Edge Enhancement: Optional sharpening kernel
Multiplanar Reconstruction (MPR): Isotropic reformatting
Clinical Applications & Protocol Setup
1. Neuroimaging (Brain)
Recommended Settings:
TR = 28 ms, TE = 10 ms, Flip Angle = 15°
1.0 mm isotropic resolution
Enable SWI mode for microbleeds
Use Cases:
Cerebral microhemorrhages
Traumatic brain injury (TBI)
Multiple sclerosis (MS) plaque detection
2. MSK (Joints & Cartilage)
Recommended Settings:
TR = 30 ms, TE = 8 ms, Flip Angle = 18°
0.8 mm slice thickness
Enable fat suppression (SPAIR)
Use Cases:
Cartilage degeneration
Labral tears (shoulder/hip)
Subtle fracture detection
Performance Metrics
Scan Time:
Full brain (1 mm iso): 5 min 20 sec
Knee (0.8 mm): 6 min 10 sec
Image Quality:
SNR (White Matter): ≥25 dB
CNR (GM/WM): ≥2.1
Geometric Distortion: <0.8%
Technologist Notes
1. Protocol Optimization
For 3T Scans: Reduce flip angle by 5° to maintain contrast
High-Res MSK: Use 0.6 mm slices + 20% oversampling
Motion-Prone Patients: Enable motion correction + 10% scan time penalty
2. Troubleshooting
Low SNR: Increase averages (NEX = 2) or reduce bandwidth
Susceptibility Artifacts: Adjust TE (±1 ms) or enable MARS-W
3. Contraindications
Not Recommended for:
Patients with non-MRI-compatible implants (unless MARS-W active)
Ultrafast dynamic studies (use 2D GRE instead)
Easy Semiconductor Technology (Hong Kong) Limited 易擇半導體科技(香港)有限公司
吉ICP备2024020526号-1
HOME
PRODUCT
TEL
MESSAGE
js