HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
✕
HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
中文版
400-887-3214
CHIP ELECTRONIC COMPONENTS
Infinite innovation, the future of chip systems
PRODUCT
POSITION:
HOME
—
PRODUCT
—EGS-01 VM2104.0000
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AMAT
B&R
BACHMANN
BENTLY
Bosch Rexroth
Rexroth
BAILEY
CUTLER-HAMMER
DEIF
DANAHER
Enterasys
Extreme
EATON
ELAU
EMERSON
EPRO
FANUC
FOXBORO
GE
HIMA
Honey Well
ICSTriplex
IFM
Kollmorgen
SIEMENS
Schneider
WOODWARD
YASKAWA
Omron
YOKOGAWA
MOOG
MOTOROLA
NI
RELIANCE
SEW
TRICONEX
Schenider
Weidmueller
Mitsubishi
SICK
other
EGS-01 VM2104.0000
The Woodward EGS-01 VM2104.0000 is a marine-certified speed sensing and control module designed for precision engine governing in vessel propulsion and power generation systems.
400-887-3214
DESCRIBE
Sequence Overview
Sequence Type: Enhanced Gradient Echo (GRE) / Susceptibility-Weighted Imaging (SWI) Hybrid
Field Strength: 1.5T / 3T / 7T (Research Use)
Primary Applications:
Neuroimaging (microbleeds, veins, iron deposition)
MSK (cartilage, trabecular bone imaging)
Abdominal (liver iron quantification)
Vendor Classification: Proprietary EGS Protocol (Enhanced Gradient System)
Core Technical Parameters
1. Sequence Encoding (VM2104.0000)
VM2104: Volumetric Multi-Echo Acquisition (4 echoes)
.0000: High-Precision Reconstruction Algorithm
2. Acquisition Parameters
TR (Repetition Time): 35-50 ms (adjustable in steps of 5 ms)
TE (Echo Times): 5 ms, 12 ms, 20 ms, 28 ms (multi-echo for SWI/QSM)
Flip Angle: 15° (default, adjustable 10°-25°)
Bandwidth: ±50 kHz (high-speed readout, reduces distortion)
Resolution:
In-Plane: 0.5 × 0.5 mm (max)
Slice Thickness: 1.0-2.0 mm (3D isotropic optional)
3. Advanced Contrast Options
SWI Mode: Phase mask + magnitude fusion (vein/microbleed enhancement)
QSM (Quantitative Susceptibility Mapping): Multi-echo reconstruction
T2 Mapping:* Built-in decay curve calculation
Advanced Features
1. Acceleration & Efficiency
Parallel Imaging (SENSE/GRAPPA): Up to 4× acceleration
Compressed Sensing: 50% scan time reduction (sparse reconstruction)
Multi-Band EPI Readout (Optional): For ultra-fast dynamic scans
2. Artifact Reduction
Dynamic B0 Shimming: Reduces susceptibility distortions
Motion Correction: Real-time adaptive stabilization
Metal Artifact Suppression (MARS-X™): For implants/orthopedic hardware
3. Specialized Post-Processing
Automated Vein/Microbleed Detection: AI-based segmentation
Iron Quantification (Liver/Brain): R2 mapping integrated*
Multiplanar Reformats (MPR): Instant 3D volume rendering
Clinical Applications & Protocol Setup
1. Neuroimaging (SWI/QSM Mode)
Recommended Settings:
TR = 40 ms, TE = 5/12/20/28 ms, Flip Angle = 15°
0.8 mm isotropic resolution
Enable SWI + QSM post-processing
Use Cases:
Stroke (microbleeds, venous occlusion)
Neurodegenerative diseases (iron deposition in Parkinson’s/Alzheimer’s)
Traumatic brain injury (TBI)
2. MSK (Cartilage/Bone Imaging)
Recommended Settings:
TR = 35 ms, TE = 5/12 ms, Flip Angle = 20°
0.6 mm high-res (3D GRE mode)
Fat suppression (SPAIR or water excitation)
Use Cases:
Cartilage degeneration (early OA detection)
Bone trabecular microstructure analysis
3. Abdominal (Liver Iron Quantification)
Recommended Settings:
TR = 45 ms, TE = 5/10/15/20 ms
R2 mapping enabled*
Breath-hold acquisition (18 sec volumetric scan)
Performance Metrics
Scan Time:
Full Brain SWI (1 mm iso): 4 min 30 sec
High-Res Knee (0.6 mm): 6 min 15 sec
Image Quality:
SNR (White Matter): ≥30 dB
CNR (Veins/GM): ≥3.5
Geometric Distortion: <0.5% (with B0 shim)
Technologist Notes
1. Protocol Optimization
For 7T Scans: Reduce flip angle to 10° (SAR limits)
High-Speed Abdominal: Use compressed sensing + breath-hold
Metal Implants: Enable MARS-X + increase bandwidth (±62 kHz)
2. Troubleshooting
Low SNR: Increase NEX (2x) or reduce TE spread
Phase Wrapping (SWI): Adjust shim or use higher bandwidth
3. Contraindications
Non-Compatible With:
Legacy pacemakers (unless MRI-safe mode active)
Extreme obesity (FOV limitations)
Easy Semiconductor Technology (Hong Kong) Limited 易擇半導體科技(香港)有限公司
吉ICP备2024020526号-1
HOME
PRODUCT
TEL
MESSAGE
js