SH31404P11A2000
The Schneider Electric SH31404P11A2000 is a Compact NSX series molded case circuit breaker (MCCB) designed for power distribution and protection in industrial, commercial, and infrastructure applications.
DESCRIBE
Parameters 1. General Specifications Parameter Specification Product Series Compact NSX Model SH31404P11A2000 Description 1400A Frame, 2000A Rated Current, 3P, Fixed Thermal-Magnetic Trip, Draw-Out Version Type Molded Case Circuit Breaker (MCCB) Mounting Style Withdrawable / Draw-Out (for fixed-mounted chassis) Number of Poles 3 Poles Trip Unit Type Fixed Thermal-Magnetic (Non-adjustable) Operation Mechanism Manual (stored-energy mechanism) 2. Electrical Ratings Parameter Specification Frame Size (Iu) 1400 A Rated Continuous Current (In) 2000 A Rated Operational Voltage (Ue) Up to 690 V AC Rated Insulation Voltage (Ui) 1000 V AC Rated Impulse Withstand Voltage (Uimp) 12 kV Rated Frequency 50/60 Hz 3. Breaking & Withstand Capacity (Note: Values depend on the specific voltage. Below are typical values at 415V AC.) Parameter Specification Ultimate Breaking Capacity (Icu) Typically 150 kA or 200 kA @ 415V AC (Must verify based on specific catalog) Service Breaking Capacity (Ics) Typically 100% of Icu (e.g., 150 kA @ 415V AC) Short-Time Withstand Current (Icw) Typically 85 kA for 1 second @ 415V AC Rated Making Capacity (Icm) Typically 220 kA (peak) @ 415V AC 4. Protection Characteristics (Thermal-Magnetic) Parameter Specification Overload Protection (Ir) Fixed. Typically set at the rated current of 2000A. Thermal element provides inverse-time protection. Short-Circuit Protection (Im) Fixed. Magnetic instantaneous trip. Typical setting is approx. 10 x In (20 kA). Tripping Curve Not adjustable. Standard thermal-magnetic curve. 5. Physical & Mechanical Parameter Specification Dimensions (W x H x D) Approximately ~325mm x ~408mm x ~220mm (for the breaker + chassis). Exact dimensions depend on the specific fixed chassis. Weight Approximately ~30 kg (breaker only). Weight increases with chassis. Connection Type Front connection for both line and load sides. Terminals Suitable for busbar or large cable connections (e.g., dual cables up to 2x400mm² per pole). Operating Positions Connected / Test / Disconnected / Withdrawn (specific to draw-out mechanism). 6. Environmental & Standards Parameter Specification Ambient Operating Temperature -25°C to +70°C (with derating above 40°C) Storage Temperature -40°C to +85°C Relative Humidity < 95% (non-condensing) Altitude Up to 2000m without derating. Protection Degree (IP) IP30 (typical for breaker in chassis mounted inside an enclosure) Standards & Certifications IEC 60947-2, GB 14048.2 (CCC), CE, RoHS compliant.
SERVICE HOTLINE Grace +86 13600179521
Mail info@hongkongeasy.com jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: 615739355
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1
js
2.181656s