Industrial Controller
All product are in stock,guaranteed delivery within 3-7 days.
Infinite Innovation, the Future of Industrial Control Systems
Infinite Innovation, the Future of Industrial Control Systems
PRODUCT POSITION:HOMEPRODUCT—SH31001P01A2000
SH31001P01A2000
The Schneider Electric SH31001P01A2000 is a Compact NSX series molded case circuit breaker (MCCB) designed for reliable power distribution and protection in various electrical installations.
DESCRIBE
Parameters 1. General Specifications Parameter Specification Product Series Compact NSX Model SH31001P01A2000 Description 100A Frame, 2000A Rated Current, 1P, Fixed Thermal-Magnetic Trip, Draw-Out Version Type Molded Case Circuit Breaker (MCCB) Mounting Style Withdrawable / Draw-Out (mounted on a fixed chassis) Number of Poles 1 Pole Trip Unit Type Fixed Thermal-Magnetic (Non-adjustable) Operation Mechanism Manual (stored-energy mechanism) 2. Electrical Ratings Parameter Specification Frame Size (Iu) 100 A Rated Continuous Current (In) 2000 A Rated Operational Voltage (Ue) Up to 690 V AC / 250 V DC Rated Insulation Voltage (Ui) 1000 V AC / 750 V DC Rated Impulse Withstand Voltage (Uimp) 6 kV (AC) / 8 kV (DC) Rated Frequency 50/60 Hz 3. Breaking & Withstand Capacity (Note: Values vary by voltage level. Below are typical maximum values.) Parameter Typical Specification @ 415V AC Ultimate Breaking Capacity (Icu) 36 kA (e.g., at 415V AC) Service Breaking Capacity (Ics) 100% of Icu (e.g., 36 kA @ 415V AC) Short-Time Withstand Current (Icw) Not applicable for fixed thermal-magnetic type Rated Making Capacity (Icm) Typically 66 kA (peak) @ 415V AC 4. Protection Characteristics (Thermal-Magnetic) Parameter Specification Overload Protection (Ir) Fixed. Set at the rated current of 2000A. Thermal element provides inverse-time protection based on standard curve. Short-Circuit Protection (Im) Fixed. Magnetic instantaneous trip. Typical setting is approximately 10 x In (20 kA). Tripping Curve Not adjustable. Standard thermal-magnetic curve (e.g., complies with IEC 60947-2). 5. Physical & Mechanical Parameter Specification Dimensions (W x H x D) Breaker module approx. ~ 50mm (1 pole width) x 160mm x 88mm. Overall dimensions depend on the specific fixed chassis. Weight Approximately ~0.8 kg (breaker only). Connection Type Front connection. Terminals Suitable for busbar or large cable connections. Operating Positions Connected / Test / Disconnected / Withdrawn (specific to draw-out mechanism). 6. Environmental & Standards Parameter Specification Ambient Operating Temperature -25°C to +70°C (with derating above 40°C) Storage Temperature -40°C to +85°C Relative Humidity < 95% (non-condensing) Altitude Up to 2000m without derating. Protection Degree (IP) IP30 (typical for breaker in chassis inside an enclosure) Standards & Certifications IEC 60947-2, GB 14048.2 (CCC), CE, RoHS compliant.
SERVICE HOTLINE Grace +86 13600179521
Mail info@hongkongeasy.com jilineasyyi@outlook.com ADDRESS Unit 12, 20th Floor, Good View Commercial Centre, 2-16 Garden Street, Mong Kok, Hong Kong
Q Q: 615739355
吉林易择科技技术发展有限公司 吉ICP备2024020526号-1