The Yokogawa EJA120E-JES5J-710ND is a high-performance micro-differential pressure transmitter designed for precise measurement of very low differential pressures in various industrial applications. This specific model features Japanese manufacturing standards with special materials and construction suitable for demanding process conditions. Utilizing Yokogawa's advanced silicon resonant sensor technology, it offers exceptional accuracy, reliability, and long-term stability for micro-pressure measurements.
Specifications
Parameter Specification
Model Code EJA120E-JES5J-710ND
Measurement Type Differential Pressure
Accuracy ±0.2% of calibrated span
Long-term Stability ±0.1% of URL per 10 years
Measurement Range 0-0.1 kPa to 0-1 kPa
Output Signal 4-20 mA DC with BRAIN protocol
Response Time Adjustable from 0.5 to 64 seconds
Operating Temperature -20°C to +60°C (electronics)
Process Temperature -20°C to +80°C
Pressure Limit 2 MPa (static pressure)
Power Supply 10.5 to 42 V DC
Enclosure Rating IP40, NEMA 1
Process Connection R1/2 (1/2 inch tube connection)
Material Construction Stainless Steel (process wetted parts)
Weight Approx. 2.5 kg
Key Features
High accuracy: ±0.2% of calibrated span
Exceptional stability: ±0.1% URL per 10 years
Stainless steel wetted parts for reliable performance
Japanese manufacturing quality
Advanced diagnostics capabilities
Easy configuration and calibration
Compact and lightweight design
Material Specifications
Process diaphragm: Stainless steel
Process flange: Stainless steel
O-ring: Fluorocarbon rubber
Housing: Aluminum die-cast
Bolts: Stainless steel
Performance Characteristics
Linearity: ±0.1% of URL
Hysteresis: ±0.05% of URL
Repeatability: ±0.05% of URL
Temperature effect: ±0.2% of URL per 10°C
Vibration effect: ±0.1% of URL at 2g, 10-200 Hz
Environmental Conditions
Ambient temperature: -20°C to +60°C
Storage temperature: -40°C to +85°C
Relative humidity: 0-90% RH
Altitude: Up to 2000 m
Electrical Specifications
Power supply: 10.5-42 V DC
Output signal: 4-20 mA DC, BRAIN digital
Load limitation: 0-600 Ω at 42 V DC
Communication: BRAIN protocol
Certifications and Standards
Safety: SIL 2 compliant