The Yokogawa ANB10D-425/CU2N is a compact-type, flange-mounted electromagnetic flowmeter from the renowned ADMAG CA series.<br />
It is designed for highly accurate and reliable volumetric flow measurement of electrically conductive liquids in a wide range of industrial applications. Its key characteristics include a small 10 mm bore size, a PTFE liner for excellent chemical resistance, and Hastelloy C-276 electrodes for use in highly corrosive processes. The integrated compact converter simplifies installation and provides standard analog and pulse output signals.
(Technical Specifications)
Parameter Category Specification Details
Model Yokogawa ANB10D-425/CU2N
Product Series ADMAG CA
Type Compact (Integral) Type Electromagnetic Flowmeter
Nominal Bore Size 10 mm (approx. 3/8")
Flange Connection JIS 10K / ANSI 150 RF Flange (Standard option, confirm specific standard)
Lining Material PTFE (Polytetrafluoroethylene)
Electrode Material Hastelloy C-276
Measured Fluid Electrically conductive liquids (≥ 5 μS/cm conductivity)
Accuracy ±0.5% of rate (for water, calibrated) or ±0.2% of rate (optional)
Output Signals • Analog Output: 4-20 mA DC, electrical isolation
• Pulse/Status Output: Open-collector, programmable for totalized flow or alarms
Power Supply • 100-240 V AC, 50/60 Hz or
• 24 V DC (Specified at order)
Communication (Optional) BRAIN or HART® communication protocol (depending on converter version) can be added for configuration and diagnostics.
Ambient Temperature -40 to 60 °C (-40 to 140 °F)
Ambient Humidity 5 to 95% RH (non-condensing)
Ingress Protection (IP) IP67 (NEMA 4X) for sensor and converter
Certifications Standard models typically comply with CE, EAC, and other international standards. Ex-proof versions are available.