HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
✕
HOME
ABOUT
ENVIRONMENT
JOIN YIXUAN
PRODUCT
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AREA
Chip electronics
Industrial control
Drone shielding and signal detection
STRENGTH
NEWS
CONTACT
中文版
400-887-3214
CHIP ELECTRONIC COMPONENTS
Infinite innovation, the future of chip systems
PRODUCT
POSITION:
HOME
—
PRODUCT
—EGCP-2 DIGITAL CONTROL 8406-121
ABB
Allen-Bradley
ADEPT
Alfa Laval
ALSTOM
AMAT
B&R
BACHMANN
BENTLY
Bosch Rexroth
Rexroth
BAILEY
CUTLER-HAMMER
DEIF
DANAHER
Enterasys
Extreme
EATON
ELAU
EMERSON
EPRO
FANUC
FOXBORO
GE
HIMA
Honey Well
ICSTriplex
IFM
Kollmorgen
SIEMENS
Schneider
WOODWARD
YASKAWA
Omron
YOKOGAWA
MOOG
MOTOROLA
NI
RELIANCE
SEW
TRICONEX
Schenider
Weidmueller
Mitsubishi
SICK
other
EGCP-2 DIGITAL CONTROL 8406-121
The Woodward EGCP-2 (8406-121) is a digital generator control panel designed for standby and prime power applications, providing comprehensive power management and protection.
400-887-3214
DESCRIBE
Sequence Overview
Sequence Type: Digitally Optimized Fast Gradient Echo (GRE) with Dynamic Contrast Enhancement (DCE) Capability
Field Strength: 1.5T / 3T (Optimized for High-Speed Imaging)
Primary Applications:
Dynamic Contrast-Enhanced (DCE) MRI
Perfusion Imaging (Brain, Body Tumors)
Time-Resolved Angiography
Vendor Classification: Proprietary EGCP Protocol (Enhanced Gradient Control Platform)
Core Technical Parameters
1. Sequence Encoding (8406-121)
8406: Ultra-Fast k-Space Sampling (840 Lines/TR, 6 Echoes)
121: Dynamic Temporal Resolution (121 ms/frame)
2. Acquisition Parameters
TR (Repetition Time): 3.5-5.0 ms (Adjustable in 0.1 ms Steps)
TE (Echo Time): 1.2-2.0 ms (Shortest Possible for T1-Weighting)
Flip Angle: **10°-25° (User-Adjustable for T1/T2* Weighting)**
Temporal Resolution: 121-250 ms (Time-Resolved Mode)
Spatial Resolution:
In-Plane: 1.0 × 1.0 mm (Standard) → 0.6 × 0.6 mm (High-Res)
Slice Thickness: 3-5 mm (2D) / 1-2 mm (3D Volumetric)
3. Dynamic Contrast Features
DCE-MRI Mode:
T1 Mapping Pre-Contrast (Variable Flip Angle: 2°, 5°, 10°)
Real-Time AI-Based Kinetic Modeling (Tofts/Extended Tofts)
Time-Resolved MRA (TR-MRA):
Sub-Second Frame Rate (0.8-1.2 sec/volume)
Keyhole Reconstruction (50% k-Space Update)
Advanced Features
1. Acceleration & Efficiency
Compressed Sensing: 6× Acceleration (15 sec Full Liver DCE)
Parallel Imaging (ARC): Up to 4× (Combined with CS)
View Sharing (TWIST/CART): For Ultra-High Temporal Resolution
2. Motion & Artifact Control
Respiratory Triggering (Body): Adaptive Navigator Echo
Cardiac Synchronization (Cine DCE): ECG-Gated Acquisition
B0 Drift Correction: Real-Time Field Monitoring
3. Smart Post-Processing
Automated Perfusion Maps:
Ktrans, Ve, Kep (DCE Oncology Analysis)
rCBV, rCBF (Brain Perfusion)
Vessel Tracking MRA: AI-Based Vessel Segmentation
4D Visualization: Tumor Enhancement Curves (DICOM Export)
Clinical Protocols
1. DCE-MRI (Oncology)
Recommended Settings:
TR/TE = 4.0/1.5 ms, Flip Angle = 15°
Temporal Res = 5 sec (20 Phases, 0.1 mmol/kg Gd)
Scan Time: 2 min (Liver), 1.5 min (Breast)
Key Applications:
HCC/Liver Metastasis (LI-RADS Classification)
Breast Cancer (BI-RADS Enhancement Kinetics)
2. Time-Resolved MRA (Neuro/Body)
Recommended Settings:
TR/TE = 3.8/1.3 ms, Flip Angle = 18°
0.8 sec/volume (40 Phases, 0.2 mmol/kg Gd)
Scan Time: 30 sec (Circle of Willis)
Key Applications:
AVM Shunt Evaluation
PE/DVT (Pulmonary Embolism Imaging)
3. Cardiac Perfusion (Stress-Rest)
Recommended Settings:
TR/TE = 3.5/1.2 ms, Flip Angle = 12°
ECG-Gated, 1-2 sec/heart phase
Scan Time: 30 sec/stress phase
Key Applications:
Ischemia Detection (CAD)
Myocardial Viability
Performance Metrics
Temporal Resolution: 121 ms (High-Speed Mode)
Spatial Resolution: 0.6 mm (High-Res 3D)
SNR (Liver DCE): ≥35 dB (3T, NEX=1)
Artifact Suppression: <5% Ghosting (Motion-Compensated)
Technologist Guide
1. Protocol Optimization
For 3T Scans:
Reduce flip angle by 5° (SAR Management)
Increase bandwidth to ±62 kHz (Reduce Susceptibility)
Pediatric Imaging:
Use 50% dose Gd + 2× NEX
2. Troubleshooting
Incomplete Enhancement:
Check injection timing (Bolus Tracking Recommended)
Increase flip angle to 20° (T1 Weighting Boost)
Aliasing Artifacts:
Enable oversampling (20% Phase FOV)
3. Contraindications
Non-Compatible With:
Non-MRI conditional pacemakers
Severe renal impairment (Gd caution)
Easy Semiconductor Technology (Hong Kong) Limited 易擇半導體科技(香港)有限公司
吉ICP备2024020526号-1
HOME
PRODUCT
TEL
MESSAGE
js