Model Foxboro 823 Series (P0926JM) Type Gauge Pressure (GP) Transmitter Output Signal 4-20 mA DC analog with superimposed HART® protocol (digital) Power Supply 10.5 to 42 V DC (standard loop power, 24V DC typical) Sensor Range (URL) 1000 psi (0 to 69 bar) - Defined by "092" code Adjustable Span Up to 100:1 turndown from the sensor's URL. Accuracy ±0.065% of calibrated span (typical for this range). Includes linearity, hysteresis, and repeatability. Sensor Technology Advanced Silicon Capacitive Process Connection 1/2" NPT Female - Defined by "J" code Wetted Parts 316L Stainless Steel diaphragm and body - Defined by "J" code Seal Material Viton® (FKM) - Defined by "M" code Housing Rating General Purpose, Weatherproof, Dustproof. Typically rated NEMA 4X (IP66). Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) (with standard fill fluid) Stability ±0.1% of URL per year for 10 years.

Model Foxboro FBM217 Module Type Analog Output (AO) Number of Channels 8 independent, isolated output channels. Output Signal 4 to 20 mA DC, user-scalable, per channel. Resolution 16-bit (high resolution for precise control). Accuracy Typically ±0.05% of full scale at 25°C (77°F). Load Capacity 0 to 750 Ohms (maximum loop resistance). Update Rate Configurable, typically every 40 to 70 milliseconds for all channels. System Compatibility Foxboro I/A Series DCS. Must be installed in a compatible FBM fieldbase (e.g., FBM200 series). Power Supply Powered by the fieldbase (typically +5V and ±12V from the power supply module). The 4-20 mA output power is sourced from the module (sourcing output). Isolation Channel-to-Channel: Yes, channels are isolated from each other. Channel-to-Bus: 500 V AC minimum. Redundancy Supports redundant (1:1) configuration. A primary and a backup FBM217 can be paired for critical control loops. Automatic switchover occurs upon failure. Diagnostics Includes comprehensive internal diagnostics for fault detection (e.g., module failure, communication loss, field short-circuit). LED Indicators Module status LEDs (e.g., OK, ACTIVE, FAIL) and often per-channel status indicators. Connections Field wiring is terminated to a removable screw terminal block on the associated fieldbase. Environmental Designed for industrial environments. Operating temperature typically 0 to 60°C (32 to 140°F).

Model Foxboro 873RS-AIPCGZ Type Absolute Pressure Transmitter Output Signal 4-20 mA DC analog with superimposed HART® protocol (digital) Power Supply 10.5 to 42 V DC (loop-powered, typical 24 V DC) Housing Rating Explosion-Proof / Flameproof - Class I, Division 1, Groups B, C, D (North America) - ATEX / IECEx: Ex d IIC T6 Gb (Europe / International) Enclosure Material Cast aluminum with a black epoxy finish. Sensor Technology Silicon Capacitive (High Accuracy) Performance / Accuracy ±0.1% of calibrated span (includes linearity, hysteresis, and repeatability). This is a high-accuracy version. Process Connection Typically 1/2" NPT female (or other as specified by "GZ" suffix). The "CGZ" code often includes 316L SST wetted parts. Pressure Ranges (URL) The "RS" indicates a specific range series. Common URL (Upper Range Limit) values are 100 inH₂O, 500 inH₂O, 1000 inH₂O, 3000 psi, etc. The exact URL is defined by the order code. Adjustable Span Up to 100:1 turndown from the sensor's Upper Range Limit (URL). Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) (with standard fill fluid) Stability ±0.1% of URL per year for 10 years. Display Optional Local Operator Interface (LOI) can be mounted on the transmitter for local readout and configuration.

Model Foxboro FCM100ET Measurement Principle Coriolis Mass Flow Primary Measurements - Mass Flow - Density - Temperature Derived Measurements - Volume Flow (inferred) - Percent Solids / Concentration - API Gravity, %Brix, etc. Outputs - Dual 4-20 mA analog outputs (user-configurable for mass flow, density, etc.) - Pulse/Frequency Output (for totalization or batch control) - Digital Communications: HART® protocol (standard), Foundation Fieldbus, or PROFIBUS PA (options) Power Supply Standard: 10.5 to 42 V DC (loop-powered for 4-20 mA) With digital comms (e.g., Fieldbus): 9 to 32 V DC Housing Rating Explosion-Proof / Flameproof - Class I, Division 1, Groups B, C, D (North America) - ATEX / IECEx: Ex d IIC T6 Gb (Europe / International) Enclosure Material Cast aluminum with epoxy paint Process Connections Varies based on the paired flow tube sensor (e.g., flanged, threaded, sanitary). The transmitter itself has conduit entries. Accuracy (Typical) - Mass Flow: ±0.10% of rate (liquid), ±0.25% of rate (gas) - Density: ±0.0005 g/cm³ (±0.5 kg/m³) - Temperature: ±1°C (±1.8°F) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Display Optional local operator interface (LOI) available for configuration and readout.

Product Type Smart Gauge Pressure Transmitter Output Signal 4-20 mA analog with HART Protocol (Rev 5/6/7) digital overlay Power Supply Loop-Powered (2-Wire). Operating Voltage: 12.5 to 36 V DC (Nominal 24 V DC). Measurement Type Gauge Pressure (Psig) Range Code (22) Must be confirmed via official range tables. For an IGP10 transmitter, 22 often corresponds to a range of 0-400 psi (0-27.6 bar). This is the most critical parameter to verify. Accuracy Typically ±0.1% of calibrated span (includes combined effects of linearity, hysteresis, and repeatability). Wetted Parts Diaphragm: Tantalum Flange: 316L Stainless Steel O-Rings: Viton® (Standard) or Kalrez®/FFKM (Option) Process Connection C1: 1/2" NPT Female Electrical Connection Not specified in model. Default is typically a 1/2" NPT conduit entry with a separate connection option code. Local Display None (Standard). An optional LCD indicator is available (would be denoted in model number, e.g., /M1). Ambient Temperature -40°C to 85°C (-40°F to 185°F) Process Temperature -40°C to 120°C (-40°F to 248°F) Protection Rating IP67 / NEMA 4X Safety Certifications Typically certified for hazardous areas by FM, FMc, ATEX, IECEx. Compliant with SIL 2/3 safety integrity levels. (Specific marks are on the product label).

product Type Smart Differential Pressure (d/p) Transmitter Output Signal 4-20 mA analog with HART Protocol digital overlay Power Supply Loop-Powered (2-Wire). Operating Voltage: 16 to 36 V DC (Nominal 24 V DC). Measurement Type Differential Pressure Range Code (B01) Must be confirmed via official range tables. For a d/p transmitter, B01 often corresponds to a range like 0-100 inH₂O (0-25 kPa) or similar. This is the most critical parameter to verify. Accuracy Typically ±0.1% of calibrated span (includes linearity, hysteresis, and repeatability). Wetted Parts Isolating Diaphragms: Tantalum (primary wetted part) Flanges: 316L Stainless Steel O-Rings: Viton® (Standard) or Kalrez®/FFKM (Option) Process Connection S1: Standard Flange Mount (e.g., with 1/4" NPT female connections on the flange). Mounting M1: With Integrated Mounting Bracket Electrical Connection L1: 1/2" NPT Conduit entry Local Display None (Standard). An optional LCD indicator is available. Ambient Temperature -40°C to 85°C (-40°F to 185°F) Process Temperature -40°C to 120°C (-40°F to 248°F) Protection Rating IP67 / NEMA 4X Safety Certifications Typically certified for hazardous areas by FM, FMc, ATEX, IECEx. Compliant with SIL 2/3 safety integrity levels. (Specific marks are on the product label).

Product Type Smart Pressure Transmitter (Likely Gauge Pressure) Output Signal 4-20 mA analog with HART Protocol (Revision 5, 6, or 7) digital overlay Power Supply Loop-Powered (2-Wire). Operating Voltage: 16 to 36 V DC (Nominal 24 V DC). Sensor Range (Code C01) Must be confirmed via official range tables. Example for a gauge pressure variant: 0-1.0 bar (0-15 psi). Note: The exact range is defined by the C01 code. Accuracy Typically ±0.1% of calibrated span (includes combined effects of linearity, hysteresis, and repeatability). Wetted Parts Diaphragm: Tantalum Flange: 316L Stainless Steel O-Rings: Viton® (Standard) or Kalrez®/FFKM (Option) Process Connection F1: 1/2" NPT Female Electrical Connection L1: 1/2" NPT Conduit Local Display None (Standard). An optional LCD indicator is available. Ambient Temperature -40°C to 85°C (-40°F to 185°F) Process Temperature -40°C to 120°C (-40°F to 248°F) Protection Rating IP67 / NEMA 4X Safety Certifications Typically certified for hazardous areas by FM, FMc, ATEX, IECEx. Compliant with SIL 2/3 safety integrity levels. (Specific marks are on the product label).

Brief Description (English): The Honeywell CSLA2EL is a rugged, high-precision limit switch designed for industrial applications requiring reliable position sensing and control. Featuring a SPDT contact configuration, it supports high electrical loads (up to 10A) and offers long mechanical/electrical life even in harsh environments. Its IP67-rated enclosure ensures resistance to dust and moisture, while the adjustable actuator allows customization for diverse mechanical setups. Ideal for automation, machinery, and safety systems, the CSLA2EL combines Honeywell’s signature durability with compliance to global safety standards.

Brief Description (English): The Honeywell PTSRB0101A2 is a high-accuracy, low-pressure transducer designed for applications requiring precise measurement of minimal pressure changes (0–1 psi). Its ratiometric 0.5–4.5V output ensures reliable signal transmission with low power consumption (5V supply). Engineered for harsh environments, it operates across an extended temperature range (-40°C to +85°C) and features an IP54-rated housing for basic dust/moisture protection. Ideal for medical devices, HVAC systems, and industrial automation, this sensor combines low hysteresis, excellent repeatability, and long-term stability. Its barbed port simplifies integration with pneumatic systems, while RoHS/CE compliance ensures global usability.

Brief Description (English): The Honeywell CLE-0052-410 is a high-precision current loop isolator designed to provide signal isolation and conditioning for 4–20 mA control systems. It ensures noise immunity, ground loop elimination, and signal integrity in industrial environments. With 1500V isolation and ±0.1% accuracy, it is ideal for interfacing sensitive instrumentation with PLCs, DCS, or SCADA systems. Key applications include process control, factory automation, and hazardous area installations (with optional ATEX certification). Its compact design, low power consumption, and robust construction make it suitable for harsh industrial conditions while complying with global safety standards.

Brief Description (English): The Honeywell CSCA0075 is a compact, high-performance pressure transducer designed for low-to-medium pressure measurement applications. Featuring a 0.5–4.5V ratiometric output, it delivers precise readings with ±1.0% FSO accuracy across a 0–75 psi range. Its rugged IP54-rated housing and wide -40°C to +85°C operating range make it suitable for industrial, HVAC, and medical applications. The barbed port simplifies installation in pneumatic systems, while RoHS/CE compliance ensures global usability.

The Honeywell X111931-GPT is a high-accuracy pressure transducer designed for industrial automation, hydraulic systems, and process control. It offers multiple output options (4–20 mA, 0.5–4.5V, or 0–10V) and supports gauge, absolute, or differential pressure measurements.