Product Type Smart Electronic Valve Positioner Brand / Series Foxboro ECKARDT SRD900 Series Supply Air Pressure Typically 1.4 - 7 bar (20 - 100 psi) Output Action Single-acting (as per code "E") Ambient Temperature Standard: -30°C to +80°C (-22°F to +176°F) Enclosure & Protection Housing Material Aluminum (typical) Ingress Protection (IP) IP66/67 (NEMA 4X equivalent), protected against powerful water jets and temporary immersion. Electrical Input Signal & Wiring 4-20 mA DC, 2-wire system (as per code "B"). The device is powered by the same 4-20 mA loop. Load Resistance Typically up to 850 Ohms at 20 mA (depending on air supply pressure). Intrinsic Safety Available options for Ex ia IIC T6 Ga (must be specified in order code). Connection Cable gland, M20 x 1.5 (as per code "Z"). Mechanical & Pneumatic Mounting Direct mounting per VDI/VDE 3845 standard (as per code "D"). Adapter kits available for other standards. Travel Sensing Mechanically coupled to the valve stem; range defined by the "SG6" code. Air Consumption Very low (in steady state, typically < 0.01 Nl/min). Flow Capacity (Cv) High, allowing for fast valve stroking. Performance & Communication Accuracy High, typically better than ±0.5% of span. Hysteresis Very low, typically < 0.1%. Communication Integrated HART® protocol. This allows for digital communication for configuration, calibration, and diagnostics using a HART communicator or asset management software. This is a standard feature in smart positioners like the SRD960.
Model Number IDP10-A22821C-M1V Product Line Foxboro I/A Series® Module Type Single-Channel, Isolated Analog Input Conditioner General Description A microprocessor-based, isolated signal conditioning module for the I/A Series DCS. It provides a single channel of analog input signal conditioning with high isolation. Input Specifications Supported Input Signals • 4 to 20 mA DC (2-wire or 4-wire transmitter) • 0 to 20 mA DC • 0 to 10 V DC • Potentiometer (Ohms) Input Impedance • Current Inputs: 50 Ohms (nominal) • Voltage Inputs: > 1 MΩ Burnout Protection User-selectable via software: • Up-scale (e.g., 22 mA) • Down-scale (e.g., 3.8 mA) • Off Isolation Channel-to-Channel: Not applicable (single channel). Channel-to-System (Field-to-Logic): 1500 VAC RMS continuous. This is a key safety feature. Output Specifications Output to System A digital value representing the input signal, communicated over the FBI bus to the host controller. Resolution Typically 16-bit or higher, ensuring high measurement accuracy. Refresh Rate Dependent on the FBI bus cycle time and system configuration. Power Supply Operating Voltage Powered by the +5V and ±15V supplies from the PSS baseplate. Loop Power (for 2-wire transmitters) Typically 24 VDC nominal, with limited current capacity (e.g., ~30 mA). Environmental & Physical Operating Temperature -40°C to +70°C (-40°F to +158°F) Storage Temperature -40°C to +85°C Relative Humidity 0 to 95% (non-condensing) Mounting Installs into a dedicated Foxboro PSS series baseplate (e.g., PSS11, PSS21, PSS31). Status Indicators (LEDs) Typically includes LEDs for Power (PWR) and Fault (FLT) status. Standards & Compliance EMC Immunity Designed to meet industrial standards for immunity to Electrostatic Discharge (ESD), Radiated RF fields, and Electrical Fast Transients (EFT).
Detection Principle Photoionization Detection (PID) Measurement Range 0-1 ppm to 0-10,000 ppm (selectable ranges, e.g., 0-10/100/1000 ppm) UV Lamp Energy Standard 10.6 eV (other options: 11.7 eV) Accuracy ±2% of reading or ±1% of full scale (whichever is greater) Response Time (T90) Typically < 3 seconds Sample Method Diffusion or pumped (integrated sample pump) Output Signals - Analog: 4-20 mA DC, isolated - Alarms: 2+ SPDT relay outputs Power Supply 24 V DC (18-30 V DC range) Display Backlit LCD (concentration, status, alarms) Enclosure Rating IP66/IP67 (dust-tight, water-resistant) Operating Temperature -20°C to +50°C Calibration Field-configurable with standard calibration gases Safety Certifications ATEX, IECEx, FM (Zone 1/Division 1 hazardous areas)
Model Code B-FXSUN-XROHS P0915FU Input Signal Type: Frequency / Tachometer Waveform: Sine Wave or Square Wave Amplitude Range: 200 mV RMS to 60 V RMS (typical) Frequency Range: 0.5 Hz to 12,000 Hz (12 kHz) Output Signal Type: 4-20 mA DC, 2-wire Load: Maximum 600 Ω (at 24V DC supply) Characteristic: Linear with input frequency. Power Supply Voltage Range: 20-30 V DC Power Consumption: Typically < 5 W Isolation Rating: 1500 V AC (between Input, Output, and Power Supply) Accuracy Typical: ±0.1% of span Response Time Configurable: Typically adjustable from 50 ms to 5.0 seconds. Safety Certifications Intrinsic Safety: Certified for Class I, Division 1, Groups A, B, C, D; Zone 0 by agencies such as FM, CSA, ATEX, and IECEx. Environmental Compliance RoHS: Compliant with the Restriction of Hazardous Substances directive. Operating Temperature -20°C to +70°C Mounting Standard 35 mm DIN Rail
Model Foxboro P0971WV DNBT Type Pressure Transmitter (Gauge/Absolute) Measurement Range 0-3000 psi (e.g., "71" may indicate 0-3000 psi range) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.065% of span (typical for 823 series) Power Supply 10.5-42 V DC (loop-powered) Process Connection 1/2" NPT Female or flanged Wetted Materials Diaphragm: 316L Stainless Steel or Hastelloy; Seals: Viton® or PTFE Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 Adjustable Turndown Up to 100:1 Certifications ATEX, IECEx, SIL 2/3, DNBT (e.g., non-incendive or DIN rail) Mounting DIN rail or direct mounting (as per "DNBT" suffix)
Model Foxboro P0916FL Type Gauge Pressure Transmitter Measurement Range 0-1000 psi (e.g., "16" may indicate 0-1000 psi range) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.065% of span (typical for 823 series) Power Supply 10.5-42 V DC (loop-powered) Process Connection 1/2" NPT Female Wetted Materials Diaphragm: 316L Stainless Steel; Seals: Viton® (FKM) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 Adjustable Turndown Up to 100:1 Stability ±0.1% of URL per year Certifications ATEX, IECEx, SIL 2/3 (depending on configuration)
Model Foxboro ICP10-T2001E-M2L1A3T Type Pressure Transmitter (Gauge/Absolute) Measurement Range 0-200 psi (e.g., "T200" may indicate 0-200 psi range) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.25% of span (typical for ICP10 series) Power Supply 12-42 V DC (loop-powered) Process Connection 1/2" NPT Female (standard) Wetted Materials 316L Stainless Steel diaphragm and body Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 Adjustable Turndown Up to 10:1 Certifications CE, RoHS (may vary by region) Electrical Connection 1/2" NPT conduit (as indicated by suffix)
Model Foxboro IMT25-IEBTB10N-B Type Multi-Variable Pressure Transmitter (DP, Static Pressure, Temperature) Measurement Range Differential Pressure (DP): 0-10 inH₂O (e.g., "10N" indicates 10 inH₂O span) Static Pressure: Up to 3600 psi (dependent on model variant) Temperature: Integrated RTD or via external sensor Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol Accuracy DP: ±0.04% of span; Static Pressure: ±0.1% of URL; Flow: ±0.5% of rate (typical) Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus) Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides) Wetted Materials Hastelloy C-276 diaphragm and seals (standard for corrosive environments) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 or FOUNDATION™ Fieldbus Adjustable Turndown Up to 100:1 Certifications SIL 2/3, ATEX, IECEx, CE Special Features Integrated flow computation, diagnostics, temperature compensation
Model Foxboro IMT25-PEATB10N-B Type Multi-Variable Pressure Transmitter (DP, Static Pressure, Temperature) Measurement Range Differential Pressure (DP): 0-10 inH₂O (e.g., "10N" indicates 10 inH₂O span) Static Pressure: Up to 3600 psi (dependent on model variant) Temperature: Integrated RTD or via external sensor Output Signal 4-20 mA DC with HART® or FOUNDATION™ Fieldbus digital protocol Accuracy DP: ±0.04% of span; Static Pressure: ±0.1% of URL; Flow: ±0.5% of rate (typical) Power Supply 10.5-42 V DC (loop-powered for HART); 9-32 V DC (Fieldbus) Process Connection 1/2" NPT or flanged (e.g., 1/4" NPT for HP/LP sides) Wetted Materials Hastelloy C-276 diaphragm and seals (standard for corrosive environments) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 or FOUNDATION™ Fieldbus Adjustable Turndown Up to 100:1 Certifications SIL 2/3, ATEX, IECEx, CE Special Features Integrated flow computation, diagnostics, temperature compensation
Model Foxboro BY3R873RS-BTWFGZ Type Pressure Transmitter (e.g., Gauge/Absolute/Differential) Measurement Range Customized (e.g., 0-1000 psi or other; "BTW" may indicate range code) Output Signal 4-20 mA DC with HART® Protocol Accuracy ±0.065% to ±0.1% of span (typical for 873 series) Power Supply 10.5-42 V DC (loop-powered) Process Connection 1/2" NPT or flanged (material: stainless steel or alloy) Wetted Materials Likely 316L Stainless Steel or Hastelloy (e.g., "FGZ" may specify materials) Housing Rating NEMA 4X (IP66) Ambient Temperature -40°C to +85°C (-40°F to +185°F) Process Temperature -40°C to +120°C (-40°F to +248°F) Protocol HART® 7 Certifications ATEX, IECEx, SIL 2/3 (depending on configuration) Calibration Factory calibrated to customer specifications
Model Foxboro HHT-AAEFNB Style-B Type Handheld Terminal (HHT) / Configurator Compatibility Foxboro field instruments (e.g., pressure/flow transmitters) Communication Protocols HART® (primary), potentially FOUNDATION™ Fieldbus or other protocols Display LCD screen (likely backlit for low-light environments) Keypad Sealed, ruggedized keys for use in harsh conditions Power Supply Rechargeable battery (e.g., Li-ion or NiMH) with AC adapter Battery Life 8-12 hours (typical per charge) Connectivity Electrical connections: 4-20 mA loop integration via test leads or connectors Operating Temperature -10°C to 50°C (14°F to 122°F) (field-use range) Enclosure Rating IP54 or higher (dust and water resistant) Software Features Device configuration, calibration, diagnostics, loop tests, data logging Certifications ATEX, IECEx (if rated for hazardous areas) Dimensions & Weight Compact and lightweight for portability (e.g., ~200-300g)
Model Foxboro FEM100 Type Fieldbus Electronic Module (FOUNDATION™ Fieldbus H1) Compatibility Foxboro I/A Series DCS (requires FMM chassis or compatible fieldbase) Protocol Support FOUNDATION™ Fieldbus H1 (IEC 61158-2) Number of Channels Typically 1 or 2 Fieldbus segments per module (varies by configuration) Power Supply 24 V DC (via chassis or external fieldbus power supply) Segment Power Provides conditioned power to Fieldbus segments (e.g., 19-23 V DC) Isolation 1500 V AC (channel-to-channel and channel-to-system) Communication Speed 31.25 kbit/s (standard Fieldbus H1 rate) Max Devices per Segment Up to 16 Fieldbus devices per segment Operating Temperature 0°C to 60°C (32°F to 140°F) Redundancy Support Yes (optional redundant configuration) Diagnostics LED status indicators for power, communication, and faults Certifications ATEX, IECEx, CE (depending on installation and region)