PRODUCT
PICTURE
BRAND
DESCRIBE
STOCK
DOWNLOAD
The TM5SDI16D is a digital input expansion electronic module designed for the Modicon™ TM5 modular I/O system. It provides 16 discrete digital input channels operating at 24 V DC with sink logic, allowing the connection of standard DC input devices such as switches, sensors, and contact closures to a compatible PLC or motion controller.
The Altivar Machine ATV320U75N4B is a compact industrial variable frequency drive (VFD) designed to control three‑phase motors in automation and machine control applications
The TM3AQ2 is a 2‑channel analog output expansion module from Schneider Electric’s Modicon TM3 series. It is designed to extend the analog output capabilities of compatible Modicon controllers (such as M221, M241, M251, and M262), providing precise voltage or current outputs for controlling field devices like drives, actuators, valves, and other analog‑controlled equipment
The TM3DQ16TK is a Modicon TM3 discrete output expansion module designed to extend the output capabilities of compatible PLCs such as Modicon M221, M241, M251, and M262 controllers. It provides 16 transistor (PNP/source logic) outputs operating at 24 V DC, suitable for switching industrial loads like indicators, relays, valves, and drive inputs.
Schneider Electric BMECRA31210 is a Modicon X80 Ethernet Remote I/O (RIO) Drop Adapter with Ethernet Backplane. It is designed for use in industrial automation systems, specifically with the Modicon M580 programmable automation controller (PAC) architecture. The adapter provides Ethernet‑based communication and remote I/O expansion for distributed automation systems.
null
The Schneider Electric ATV71HC16N4 is a high‑performance variable frequency drive (VFD) designed for controlling three‑phase electric motors in demanding industrial applications.
null
The Schneider Electric TM200C32T is a compact programmable logic controller (PLC) from the Easy Modicon M200 series, designed for small to medium‑sized automation and control systems.
Product Type Gauge Pressure Transmitter Measurement Principle Advanced sensor (e.g., Silicon Resonant) Output Signal 4-20 mA analog output with HART® Protocol Accuracy High, typically ±0.075% of span Pressure Range (URL) Example: 0-1600 kPa (based on code J) Process Connection Flush-mounted diaphragm (based on code M) Wetted Parts Material 316L Stainless Steel (based on code A) Power Supply 2-wire, 12-45 VDC (loop-powered) Operating Temperature -40°C to +85°C (ambient) Protection Rating NEMA 4X / IP67
Product Type Compact Magnetic Flowmeter (Integrated Transmitter and Tube) Measurement Principle Faraday's Law of Electromagnetic Induction Measured Media Electrically conductive liquids (typically with a conductivity > 5 μS/cm) Line Size 3-inch (DN80), based on code J Liner Material PTFE (Teflon®), based on code 1 Electrode Material 316L Stainless Steel, based on code F Accuracy Typical: ±0.5% of rate Output Signal 4-20 mA analog, pulse/frequency, typically with HART® Protocol Power Supply 100-240 VAC or 24 VDC (dependent on specific order code) Protection Rating Typically NEMA 4X / IP67 for field mounting
Model Number P0914LV Product Type Gauge Pressure Transmitter Pressure Type Gauge Pressure (pressure relative to atmospheric pressure) Sensor Technology Advanced high-stability sensor (e.g., silicon resonant or capacitive) Output Signal 4-20 mA analog output with HART® Protocol for digital communication. Accuracy High accuracy. For low-pressure "LV" models, this is often ±0.075% of the Upper Range Limit (URL) or calibrated span. Pressure Range (URL) The "LV" code is critical and typically indicates a low pressure range. The "14" in P0914LV often correlates to a specific range, such as 0-14 kPa (0-2 psi, 0-56 inches of water column). Process Connection Low-pressure ports, often 1/4" NPT or similar, suitable for low-pressure gases. Wetted Parts Material 316L Stainless Steel is standard. Power Supply Standard 2-wire, 12-45 VDC loop-powered operation. Operating Temperature Ambient: -40°C to +85°C (-40°F to 185°F). Process: Dependent on seal options. Protection Rating NEMA 4X / IP67 (weatherproof and corrosion-resistant).
Product Type Rack-mounted Intelligent Pressure Module Integrated System Foxboro I/A Series DCS Measurement Type Differential Pressure (DP) Typical Range (URL) Example: 0-400 inH₂O (approx. 0-100 kPa) - specific to the H code. Accuracy Very high, typically better than ±0.1% of span. Output Signal Digital communication directly to the I/A Series controller via the system's backplane or proprietary bus. Power Supply Powered via the I/A Series rack backplane. Process Connection External wiring terminals for connecting wires from the field (e.g., from a remote seal or impulse lines). Operating Temperature Designed for a controlled cabinet environment. Primary Application Flow Measurement (with primary elements like orifice plates) and Level Measurement.
Model Number AD207AU Function Type Dual-Channel Analog Signal Isolator / Converter Input Signal According to Foxboro's naming convention, "A" typically stands for a DC Current Input (e.g., 4-20 mA). Output Signal According to Foxboro's naming convention, "U" typically stands for a DC Voltage Output (e.g., 1-5 VDC, 0-10 VDC). Number of Channels 2 independent channels (as indicated by the "AD207" base model). Power Supply Requires an external power source, typically 24 VDC. Isolation Channel-to-channel isolation and channel-to-power supply isolation (typically 1500 VAC). Accuracy High typical accuracy, e.g., ±0.1% of span. Input Burden The voltage drop caused by the input current is typically very low (e.g., <3V). Voltage Output Load The voltage output can typically drive a minimum load resistance (e.g., 1 kΩ). Response Time Very fast, typically less than 100 ms. Operating Temperature -20°C to +70°C (standard industrial range). Mounting Standard 35mm DIN rail mounting. Certifications Typically carries international certifications like CE, ATEX, IECEx, FM for use in hazardous areas.